Assembly instructions
DACeco
14
PE
N
L3
L2
L1
DAC
DAC
TN
-
Netz
The following applies to TT mains and IT mains:
All units protected jointly by one protective device must be connected to the same earthing device by a
protective earth.
Simultaneously exposed units must be connected to a joint earth.
The following applies additionally to IT mains:
No active conductor of the unit must be earthed directly. The units must be connected individually, in groups or
in their entirety to a protective earth.
Mono-phase plug connection